- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources2
- Resource Type
-
0000000002000000
- More
- Availability
-
20
- Author / Contributor
- Filter by Author / Creator
-
-
O’Connor, Sean_P (2)
-
Scully, Marlan_O (2)
-
Yakovlev, Vladislav_V (2)
-
Denton, Michael_L (1)
-
Doktor, Dominik_A (1)
-
Noojin, Gary_D (1)
-
Pope, Nathaniel_J (1)
-
Powell, Samantha_M (1)
-
Rickman, John_M (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Brillouin microscopy has recently emerged as a powerful tool for mechanical property measurements in biomedical sensing and imaging applications. Impulsive stimulated Brillouin scattering (ISBS) microscopy has been proposed for faster and more accurate measurements, which do not rely on stable narrow-band lasers and thermally-drifting etalon-based spectrometers. However, the spectral resolution of ISBS-based signal has not been significantly explored. In this report, the ISBS spectral profile has been investigated as a function of the pump beam’s spatial geometry, and novel methodologies have been developed for accurate spectral assessment. The ISBS linewidth was found to consistently decrease with increasing pump-beam diameter. These findings provide the means for improved spectral resolution measurements and pave the way to broader applications of ISBS microscopy.more » « less
-
Mammalian complex III heme dynamics studied with pump-probe spectroscopy and red light illuminationsO’Connor, Sean_P; Powell, Samantha_M; Rickman, John_M; Pope, Nathaniel_J; Noojin, Gary_D; Scully, Marlan_O; Denton, Michael_L; Yakovlev, Vladislav_V (, Biomedical Optics Express)The electronic or molecular mechanisms that initiate photobiomodulation (PBM) in cells are not yet fully understood. The porcine complex III (C-III) of the electron transport chain was characterized with transient absorption spectroscopy (TAS). We then applied our recently developed continuous wave laser coupled TAS procedure (CW-TAS) to investigate the effect of red light irradiances on the heme dynamics of C-III in its c1reduced state. The time constants were found to be 3.3 ± 0.3 ps for vibrational cooling of the oxidized state and 4.9 ± 0.4 ps for rebinding of the photodissociated axial ligand of the c1reduced state. The analysis of the CW-TAS procedure yielded no significant changes in the C-III heme dynamics. We rule out the possibility of 635 nm CW light at 4.7 mW/cm2inducing a PBM effect on the heme dynamic of C-III, specifically with the photodissociation of its axial ligand.more » « less
An official website of the United States government
